Our company supplies self-made high precision hydrometers, refractometers as well as measuring systems to determine the alcohol in alcoholic beverages and tests for the wine analysis.
In this regard it has always the aim of our company - in dialogue with the customer - to deliver top quality at payable (favourable) prices and at the same time securing advise before and after sale. The result of which is: We have become a reliable partner for our customers and dealers in our region as well as on an international level.
Our webshop offers a broad sortiment as well as service. Register yourself in order to receive further information. Customers are being supplied with all important information via our newsletter regarding new articles and special offers.
For the easy and accurate determination of the alcoholic strength (ethanol) in wine, must, liqueur and sparkling wine as well as the determination of the extract in winebased on distillation Function (Principle): The volumetric flask (100 ml) is filled with 100 ml of wine, liqueur etc. (thick-flowing liqueurs and mashes have to be diluted). This sample is poured into the distillation flask, which is put on a heating plate, a kitchen stove or similar. The empty volumetric flask (100 ml) is placed below the condenser discharge. Now the power is turned on and the water tap is opened. After approx. another 12 minutes, ca. ¾ of the volumetric flask will be filled and the heating is turned off. The remaining extract does not contain any alcohol anymore. The distillate is now filled up with water until 100 ml and then decanted into the special measuring cylinder. The alcohol content of the liquid in the cylinder is then determined by means of a Euro Class III alcoholometer (according to DIN 12803 = graduation in steps of 5, Ø 23 mm). To obtain accurate measuring results, the user must make sure that the original sample liquid, the distillate obtained from that sample and the distilled water (needed to fill up of the distillate) have all more or less the same temperature (not necessarily 20 °C). If time is not important to the user, it is sufficient to store the mentioned liquids at room temperature. However, if the liquids are not at 20 °C, the measuring result has to be corrected with our temperature-correction nomogram or an official alcohol table or similar.
Scope of delivery: Distillation apparatus with ground joint including distillation flask (glass) User manual Hose ( 2 m feed hose , 2 m discharge hose, 0.2 m distillate delivery hose with ¾" connection) Stand glass cylinder with base and ring (plastic) Measuring flask ,100ml (glass) with stopper Sample bottle, 250ml (plastic) Tube of joint grease (made on the basis of silicone) Antifoaming agent (bottle) Boiling stones (glass) Wash bottle, 250 ml (plastic) for distilled water Lead ring Pipette, 3 ml (plastic) List of results Sample spoon (plastic) 280,25 EUR incl. 19 % Tax excl.
Our PAL has received 2003 “Good Design Award” 2004 “Venture Technology Awards (Excellence)” 2005 “Technology for Food Industry Award”
Light & Compact, 100g. Ergonomically designed for one-handed operation.
Sample size 2-3drops.
The speedy performance of the PAL is amazing. Simply put a drop of a sample on the prism surface and press the START key. The Brix value ( sugar content / concentration ) will be displayed in just 3 seconds.
High temperature sample can be measured.
Protection class of the PAL is IP65. You can rinse off the sample by running water on the sample stage. The design allows the user to easily wipe off the sample.
Our PAL has received 2003 “Good Design Award” 2004 “Venture Technology Awards (Excellence)” 2005 “Technology for Food Industry Award”
Light & Compact, 100g. Ergonomically designed for one-handed operation.
Sample size 2-3drops.
The speedy performance of the PAL is amazing. Simply put a drop of a sample on the prism surface and press the START key. The Brix value ( sugar content / concentration ) will be displayed in just 3 seconds.
High temperature sample can be measured.
Protection class of the PAL is IP65. You can rinse off the sample by running water on the sample stage. The design allows the user to easily wipe off the sample.
The RX-7000α ( alpha ) is an improved ( upgraded ) model for a measurement range of refractive index and measurement temperature of an RX-5000α ( alpha ). The thermo module for constant temperature is equipped. It is best for measuring oils and fats of high melt point, higher refractive index perfumes, organic solvents, etc. The RX-7000α ( alpha ) has the manual calibration facility which compensate difference in standard liquids and measurement values by other refractometers. This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
Model
RX-7000α
Cat.No.
3262
Measurement Range
Refractive index (nD) 1.3250 to 1.7000 Brix 0.00 to 100.0% (ATC : 5 to 70°C)
Refractive index (nD) : ±0.0001 *±0.00005 Brix ±0.1% *±0.02% [*1]
Measurement Temperature
5 to 70°C
Power Supply
AC100V to 240V, 50/60Hz
Power consumption
65VA
Dimensions & weight
37×26×14cm, 6.8kg (Main Unit only)
Mode
MODE-1: Displays the measurement value once the sample reaches the target temperature.
MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
MODE-S: Displays the measurement value once a certain level of sample stability is achieved.
Output terminals
• Printer (for ATAGO digital printers) • Computer - RS-232C Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty
2 years standard (3 years with product registration)
• Printer paper (regular) for DP-62α, DP-RX : RE-8412 • Printer paper (long-term storage) for DP-62α, DP-RX : RE-8414 • Printer paper for DP-RD : RE-89403 • Ribbon cassette for DP-RD : RE-89402 • Fan Filter Replacement : RE-58001
[*1] When measuring a standard sucrose solution of up to 50% Brix or standard refractive index solution in MODE-1 at 20°C
The listed prices are recommended prices! 9.568,79 EUR incl. 19 % Tax excl.
The "Pocket" Honey Refractometer, PAL-22S can measure the % water content of honey easily and displays readings digitally. Comfortable, easy to use, light & compact. Measurements can be taken anywhere. Measurement range: 12-30 % Honey moisture, Temperature 10.0 to 40.0°C
Model
PAL-22S
Cat.No.
4422
Measurement Range
Honey moisture 12.0 to 30.0 % Temperature 10.0 to 40.0°C
This refractometer is a compact in-line model which can be incorporated in piping of manufacturing plants, or a liquid mixing apparatus, or a washing apparatus to continuously measure concentration ( Sugar content : Brix ) and is suitable for use in control of mixing or concentrating processes at food manufacturing plants, in control of fermentation equipment ( alcohol, soysouce, etc. ), in control of concentration of water-based or alkali-based detergent, etc.
Model
CM-780N
Cat.No.
3561
Measurement Scale
Brix ( Automatic Temperature Compensation according to the sample liquid )
Measurement Range
Brix 0.0 to 78.0%
Minimum Indication
Brix 0.1%
Measurement Accuracy
Brix ±0.2%
Measurement Temperature
5 to 100°C ( Automatic Temperature Compensation )
Ambient Temperature
5 to 40°C
Power Consumption
3VA
Output
(1) Recorder output : DC 4 to 20mA (2) RS-232C output
Materials in contact with the Solution
Prism : Sapphire Prism stage : SUS316
Power Supply
DC24V
International Protection Class
IP64 Dust-tight and Protected against splashing water.
Dimensions & Weight
16×17×11cm, 1.8kg (Main Unit only)
Accessory
Power input cable ( 1m )
Optional
* Calibration Certificate : Contact an ATAGO representative for details. As for the other optional see below.
Accessories
Sampe Inlet Unit
AC Adapter
Stand
Hose connector 12mmΦ RE-6645
JIS Flange 1.25S×25A RE-6667
The AC adapter used to convert AC100 - 240V to DC24V and to supply power to the CM-780N.
AD-32 (AC100V) Cat.No.3527
AD-33 (AC110 to 120V) Cat.No.3528
AD-34 (AC220 to 240V) Cat.No.3529
Stand for mounting the CM-780N and the AC adapter.
RE-8607
Compression Fitting 10mmF RE-6651
DF/ISO Clampunion (ferrule) 1S RE-6658
IDF/ISO Clampunion (ferrule) 2S RE-6659
Parts No.
Names
RE-6645
Sample inlet unit • hose connector 12mmΦ
RE-6651
Sample inlet unit • Compression fitting 10mmΦ
RE-6667
Sample inlet unit • JIS Flange 1.25S×25A
RE-6668
Sample inlet unit • JIS Flange 50A
RE-6658
Sample inlet unit • IDF/ISO Clampunion (ferrule) 1S
RE-6659
Sample inlet unit • IDF/ISO Clampunion (ferrule) 2S
RE-6676
Sample inlet unit • IDF/ISO Clampunion (ferrule) 1.5S
RE-5635
Recorder output cable with 1 connector (5m)
RE-5636
Recorder output cable with 1 connector (10m)
RE-5638
Recorder output cable with 1 connector (15m)
RE-5639
Recorder output cable with 1 connector (20m)
RE-5647
RS-232C output cable with connector (15m)
RE-8607
Stand (Stand for mounting the CM-780N and the AC adapter)
Cat.No.3527
AC adapter AD-32 ( AC100V )
Cat.No.3528
AC adapter AD-33 ( AC110 to 120V )
Cat.No.3529
AC adapter AD-34 ( AC220 to 240V )
Recommended prices!
4.367,30 EUR incl. 19 % Tax excl.
Shopping Cart