Automatic Polarimeter AP-300

Cat.no. R 5291   

The AP-300 fully automatic polarimeter measures a sample easily by setting the observation tube ( filled with a liquid sample ) in the sample chamber and pressing START.
Digitally displayed measurement values are large and easy to read. The AP-300 generally used in pharmaceutical, perfume, cosmetic, industrial, chemical, and food factories is the best for measuring the angle of rotation. In addition, the built in International Sugar Scale is used widely in sugar factories.

 

Specifications:  
Measurement Scales

Angle of Rotation

+ 89,99° bis 0° bis - 89,99°
Measurement Scales

International Sugar Scale

+ 130°Z bis 0°Z bis - 130°Z temperaturecompensated

+ 130°Z bis 0°Z bis - 130°Z not temperaturcompensated

Division Angle of Rotation: 0,01 °
Division International Sugar Scale: 0,01 °Z
Accuracy: Angle of Rotation: ± 0.01°
International Sugar Scale: ± 0.03°Z
Calibration Enables manual calibration by measuring a standard Quartz Plate
Wavelength 589nm (D-line)
Light source: LED mit Interferenzfilter (589 nm)
Dimensions & Weight 48.5×28.5×17.5cm, 11.5kg
Lichtquelle: Halogenlamp
Accessories 100mm ( 5ml ) , 200mm ( 10ml ) Observation tube ( 1each )
Output Terminals •Digital Printer DP-63 or DP-AD  ( Optional )
•RS-232C
Optional
•Special Packages Type A Temperature Controlled : Cat.No.5296
•Special Packages Type B Temperature Compensation : Cat.No.5297
•Digital Printer DP-63 : Cat.No.3118
•Digital printer DP-AD : Cat.No.3123
•Observation tube 100mm long OT-100 (A) : RE-72001
•Observation tube 200mm long OT-200 (A) : RE-72002
•Jacketed flow tube 100mm : RE-72034
•Jacketed flow tube 200mm : RE-72035
•Jacketed flow tube 50mm : RE-72036
•Jacketed flow tube with funnel 100mm : RE-72033
•Jacketed flow tube with funnel 200mm : RE-72032
•Quartz control plate 34° : RE-72013
•Quartz control plate 17° : RE-72014
•Quartz control plate 8.5° : RE-72015
•Quartz control plate ISS 25°Z : RE-72016
•Quartz control plate ISS 50°Z : RE-72017
•Quartz control plate ISS 99°Z : RE-72018
RE-72001
RE-72002
RE-72009
RE-72010
RE-72011
RE-72012
RE-72013
RE-72014
RE-72015


Special Package (Recommended for sugar industry)

ATAGO has prepared 2 different AP-300 packages for the sugar industry. Users have a choice between 2 types: Temperature Controlled Type A and Temperature Compensation Type B. The AP-300 comes with Automatic Temperature Compensation for International Sugar Scale. A Circulating Constant Temperature Bath is not necessary when the temperature compensation function is used or when the AP-300 is used in a temperature-controlled room.

Model Type A
Temperature Controlled
Type B
Temperature Compensation
Cat.No. 5296 5297
Package Contents · AP-300 (including accessories)

· Jacketed flow tube with funnel and temperature sensor for jacket (200mm - approximate volume 15ml)

· AP-300 (including accessories)
· Unjacketed flow tube with funnel (200mm - approximate volume 15ml)

 

Home