Since more then 50 years KUEBLER hydrometers made of glass are indispensable precision measurement instruments in laboratories and for the controlling of production lines. 

Our hydrometers have a precision of up to 0.0001 g/cm³ or rather 0.00005 g/cm³ resolution upon special customer request, alcoholometers with an error range of 0,01-0,007 %vol (!), all products deliverable with/ without integ. thermometer, we offer many types for all possible applications and industries; 

The production is according to DIN, BS, ASTM, A.P.I. Of course, we easily excel the requirements specified by the PTB (Physikalisch-Technische Bundesanstalt). On request, we can also supply with internationally recognised DKB certificate (ILAC). Our instruments are produced for precisely measuring the density, Baumé, Twaddle, alcoholometers in vol%, saccharimeters in %mas / Brix / Balling, refractometers, lactodensimeter for example acc. to Gerber, and Quevenne. Last but not least, our products are available with official calibration, DKD calibration or works calibration. Manufactured acc. DIN 12792, 12791, 18123, 12804, BS 718, 734, 1377, ASTM E100

Please choose from the following categories:

1. HYDROMETERS FOR DENSITY MEASUREMENT

Aräometer entsprechend/
hydrometers according:

a) ISO 649,
DIN 12791 neu,
BS 718,
NF B35511:
L 20,

L 50

M 50

S 50,

M 100

b)   ASTM

Other hydrometers

2. HYDROMETERS FOR DETERMINATION OF DEGREES BAUME

3. HYDROMETERS FOR DISTILLERS & LIQUOR INDUSTRY

4. HYDROMETERS FOR BEVERAGE INDUSTRY & WINE-GROWERS

5. HYDROMETERS FOR BREWING INDUSTRY

6. HYDROMETERS FOR MILK PRODUCTION & DAIRING

7. HYDROMETERS FOR PETROCHEMICAL INDUSTRY & GAS PRODUCERS

8. HYDROMETERS FOR SUGAR INDUSTRY & CONFECTIONERY

9. HYDROMETERS FOR SPECIAL APPLICATIONS

You can – nearly - demand our complete range comprising approximately 1.500 different hydrometers applicating our hydrometer searching-machine. If you will not find the requested hydrometer do not hesitate to contact us.

When placing your order the following has to be considered:

Reference temperatures

The specific reference temperatures has to be strictly observed to gain perfectly accurate results. In case of deviating measuring temperatures corresponding corrections have to be carried out to yield accuracte results.

Surface tension

When choosing the hydrometer the surface tension has to be observed. 

Further information hereto.

Hydrometer readings

Non-transparent liquids have to be read <above<, whereas transparent ones can be read <below>.

Measuring accuracy

KUEBLER is in a position to deliver hydrometers extremely precise gathering from several national certificates, e.g. calibration certificate of the Technical High Authority of Germany for Measuring Regulations (PTB) disposing of utmost test technology.

Further information hereto.

Design of the hydrometers

KUEBLER uses optimal readable deep red ( non-toxic) thermometer liquid, easily and comfortable readings of the capillaries and even scales (even: better readable than round ones). Mercury – Hg – has to be used as reading liquid for gaugeable / gauged instruments.

Everyone of our instruments can be equipped with a beautiful easily readable coloured scale (You certainly do not have a TV in black/white version).

E.g. this is the design of the scale for the hydrometer, article no. 310900.

Our hydrometers are made of soda glass.

Measuring applications

Perfect measuring results can be achieved by using the HYDROMETER-MEASURING SYSTEM OPTIMUM (special kardanic stand, impact-protection glass magnifier, suitable measuring glass.

Thereby all normal difficulties encountered in hydrometer measurement are abolished. Hydrometric measuring will be easy and quick under the complete using of the accuracy.

Further informationen hereto.

Keeping of the hydrometer

For the handy and diagonal setting-up of the hydrometers on the laboratory table we offer a special unit; furthermore we are delivering a wadded box to keep them in stock, e.g. for complete sets.

Miscellaneous

Each hydrometers is equipped with a detailed instruction manual, as we found out, that without considering the instruction measuring faults can occur.

As represented KUEBLER is leading in great fields of the hydrometrie. You have to consider that there a great differences in the quality!
You can surely trust us. Place your order with us! 

ACCESSORIES

K 1503 Hydrometer-Keeping unit, 4 places
K 1504 Hydrometer-Keeping unit, 6 places  

CARDANIC STAND    

Art.Nr.

 L 2000

The special cardanic stand developed by KUBLER consists of a heavy metal base, a shaft, a cardanic suspension designed for the insertion of glass cylinders with outside diameters of 63 mm. By using a variety of comparatively inexpensive reducing adapters, one can also insert glass cylinders with smaller outside diameters than the afore-stated 63 mm (and, thus, smaller impact-protection inserts) into the cardanic suspension. So that if is not necessary to buy a multitude of cardanic suspensions specifically dimensioned for the different outside diameters of the different glass cylinders one wishes to use with that stand - which, by the way, would be quite costly, given that those cardanic suspensions are rather expensive. The dimensions of the reducing adapters, the impact-protection glass inserts, and the cardanic suspension itself having been chosen to accommodate standard-size KÜBLER stand/measuring cylinders, only KÜBLER stand/measuring cylinders can be used in that cardanic suspension without difficulty. In order to hang it into the cardanic suspension, those KÜBLER stand/measuring cylinders must be equipped with 0-rings.

 
Glasscylinder

Art.No.

a)

AZ00030, AZ00040, AZ00050 -> reducing piece:

L 2001

b)

AZ00051, AZ00060, AZ00070, AZ0080 -> reducing piece:

L 2002

c)

AZ00090, AZ001000 -> O-ring (reducing piece not necessary):

L 2003

*

 

This magnifying glass features a highly powerful Ions. The magnifying glass being attached to the cardanic stand by Volcro fastener, it can be removed from the stand with one quick grasp of a hand and may then be re-installed on the stand in a different position or used for a different purpose. 

L 2006

* Spezial-standcylinder
By using Euro-Alkoholometer EG Kl. II with a range 5 % vol.(for example 35-40 %) you need only 100 ml sample with following cylinder:
 

glasscylinder

K 1177

 

and reducing piece + o-ring

L 2004

 

By using Euro-Alkoholometer with a range 10 % vol.(for example 30-40 %) you need only 300 ml sample with following cylinder:

glasszylinder K1198
and reducing piece + o-ring L 2007

Padded boxes upon request (by stating the quantity of the instruments to be held in stock and their dimensions).